The MAX809MEUR+T10 is a three-pin device with the following pin configuration:
Advantages: - Wide supply voltage range allows compatibility with different systems - Adjustable reset threshold and timeout options provide flexibility - Low quiescent current consumption helps conserve power - Open-drain RESET output simplifies interfacing
Disadvantages: - Limited number of reset threshold voltage and timeout period options - SOT-23-3 package may not be suitable for all applications requiring voltage supervisors
The MAX809MEUR+T10 operates by continuously monitoring the supply voltage. When the voltage falls below the programmed threshold, the reset output is asserted, indicating a power failure or brownout condition. The reset remains active until the voltage rises above the threshold and the timeout period elapses.
The MAX809MEUR+T10 is commonly used in various applications, including: - Microprocessor-based systems - Embedded systems - Industrial control systems - Consumer electronics - Battery-powered devices
Note: This is not an exhaustive list of alternative models. Please refer to the manufacturer's datasheet for a complete list of alternatives.
Word count: 314 words
What is the operating voltage range of MAX809MEUR+T10?
- The operating voltage range of MAX809MEUR+T10 is 1.0V to 5.5V.
What is the typical reset threshold voltage of MAX809MEUR+T10?
- The typical reset threshold voltage of MAX809MEUR+T10 is 4.63V.
Can MAX809MEUR+T10 be used in battery-powered applications?
- Yes, MAX809MEUR+T10 can be used in battery-powered applications due to its low quiescent current.
What is the output type of MAX809MEUR+T10?
- MAX809MEUR+T10 has an active-low push-pull output.
Is MAX809MEUR+T10 suitable for use in automotive electronics?
- Yes, MAX809MEUR+T10 is suitable for use in automotive electronics as it meets AEC-Q100 specifications.
What is the temperature range for operation of MAX809MEUR+T10?
- MAX809MEUR+T10 has an operating temperature range of -40°C to +125°C.
Does MAX809MEUR+T10 have a manual reset input?
- No, MAX809MEUR+T10 does not have a manual reset input.
Can MAX809MEUR+T10 be used in industrial control systems?
- Yes, MAX809MEUR+T10 is suitable for use in industrial control systems due to its robust design.
What is the typical power-on reset time of MAX809MEUR+T10?
- The typical power-on reset time of MAX809MEUR+T10 is 20ms.
Is MAX809MEUR+T10 available in a small package for space-constrained applications?
- Yes, MAX809MEUR+T10 is available in a SOT23-3 package, making it suitable for space-constrained applications.