The MAX708RCUA-T has the following pin configuration:
| Pin Number | Pin Name | Description | |------------|----------|-------------| | 1 | GND | Ground | | 2 | RESET | Reset Output| | 3 | VCC | Supply Voltage | | 4 | TH | Threshold Voltage Selection | | 5 | MR | Manual Reset Input | | 6 | GND | Ground | | 7 | GND | Ground | | 8 | GND | Ground |
The MAX708RCUA-T operates by continuously monitoring the supply voltage using an internal voltage reference and comparator. When the voltage drops below the selected threshold, the reset output is activated, signaling a low-voltage condition. The reset remains active until the voltage rises above the threshold or a manual reset signal is applied.
The MAX708RCUA-T finds applications in various fields where voltage monitoring and system reset functionality are crucial. Some potential application areas include:
These alternative models offer similar voltage monitoring and reset functionalities, catering to different package preferences and additional features.
Word count: 422
Question: What is the operating voltage range of MAX708RCUA-T?
Answer: The operating voltage range of MAX708RCUA-T is typically between 1.0V and 5.5V.
Question: What is the maximum supply current of MAX708RCUA-T?
Answer: The maximum supply current of MAX708RCUA-T is typically 10µA.
Question: Can MAX708RCUA-T be used as a power-on reset circuit?
Answer: Yes, MAX708RCUA-T is commonly used as a power-on reset circuit to monitor the power supply voltage and generate a reset signal when it falls below a certain threshold.
Question: What is the typical reset threshold voltage of MAX708RCUA-T?
Answer: The typical reset threshold voltage of MAX708RCUA-T is 4.63V.
Question: Does MAX708RCUA-T have a manual reset input?
Answer: No, MAX708RCUA-T does not have a manual reset input. It generates a reset signal automatically based on the monitored voltage.
Question: Can MAX708RCUA-T be used in battery-powered applications?
Answer: Yes, MAX708RCUA-T is suitable for battery-powered applications due to its low supply current and wide operating voltage range.
Question: What is the typical reset timeout period of MAX708RCUA-T?
Answer: The typical reset timeout period of MAX708RCUA-T is 140ms.
Question: Is MAX708RCUA-T available in different package options?
Answer: Yes, MAX708RCUA-T is available in a 8-pin µMAX package.
Question: Can MAX708RCUA-T be used in automotive applications?
Answer: Yes, MAX708RCUA-T is automotive qualified and can be used in automotive applications.
Question: Does MAX708RCUA-T have a low-power consumption mode?
Answer: Yes, MAX708RCUA-T has a low-power consumption mode that can be activated by connecting the MR (Master Reset) pin to VCC.