画像はイメージの場合もございます。
商品詳細は仕様をご覧ください。
ADS8319IDRCR

ADS8319IDRCR

Product Overview

Category

The ADS8319IDRCR belongs to the category of analog-to-digital converters (ADCs).

Use

This product is used to convert analog signals into digital data for processing and analysis in various applications.

Characteristics

  • High-resolution: The ADS8319IDRCR offers a resolution of up to 16 bits, ensuring accurate conversion of analog signals.
  • Fast sampling rate: With a maximum sampling rate of 1 MSPS (Mega Samples Per Second), it can capture high-frequency signals effectively.
  • Low power consumption: This ADC is designed to operate with low power consumption, making it suitable for battery-powered devices.
  • Wide input voltage range: It supports a wide input voltage range, allowing it to handle various signal levels.
  • Integrated features: The ADS8319IDRCR includes built-in reference voltage, temperature sensor, and programmable gain amplifier.

Package and Quantity

The ADS8319IDRCR is available in a small form factor package, specifically the DRC (VQFN) package. It is supplied in tape and reel packaging, with a quantity of 2500 units per reel.

Specifications

  • Resolution: Up to 16 bits
  • Sampling Rate: Up to 1 MSPS
  • Input Voltage Range: ±10 V
  • Power Supply: 2.7 V to 5.5 V
  • Operating Temperature Range: -40°C to +125°C
  • Package Type: DRC (VQFN)

Pin Configuration

The ADS8319IDRCR has a total of 20 pins. Here is the detailed pin configuration:

  1. REFOUT: Reference voltage output
  2. AGND: Analog ground
  3. VREFP: Positive reference voltage input
  4. VREFN: Negative reference voltage input
  5. VIN: Analog input voltage
  6. VIN: Analog input voltage
  7. VIN: Analog input voltage
  8. VIN: Analog input voltage
  9. VIN: Analog input voltage
  10. VIN: Analog input voltage
  11. VIN: Analog input voltage
  12. VIN: Analog input voltage
  13. VIN: Analog input voltage
  14. VIN: Analog input voltage
  15. VIN: Analog input voltage
  16. VIN: Analog input voltage
  17. VIN: Analog input voltage
  18. VIN: Analog input voltage
  19. VIN: Analog input voltage
  20. DGND: Digital ground

Functional Features

  • High-resolution conversion of analog signals to digital data.
  • Programmable gain amplifier allows for signal amplification and adjustment.
  • Integrated reference voltage and temperature sensor for accurate measurements.
  • SPI (Serial Peripheral Interface) communication interface for easy integration with microcontrollers.

Advantages and Disadvantages

Advantages

  • High resolution ensures precise conversion of analog signals.
  • Fast sampling rate enables capturing of high-frequency signals.
  • Low power consumption makes it suitable for battery-powered devices.
  • Wide input voltage range allows for handling various signal levels.
  • Integrated features simplify the design and reduce external components.

Disadvantages

  • Limited number of input channels compared to multi-channel ADCs.
  • Requires an external microcontroller or processor for data processing and analysis.

Working Principles

The ADS8319IDRCR operates based on the successive approximation register (SAR) architecture. It samples the analog input voltage, compares it to a reference voltage, and generates a digital representation using a binary search algorithm. The programmable gain amplifier allows for signal conditioning and amplification before the conversion process.

Application Field Plans

The ADS8319IDRCR is widely used in various applications, including:

  1. Industrial automation: Precise measurement and control systems.
  2. Medical equipment: Vital sign monitoring and diagnostic devices.
  3. Test and measurement instruments: Data acquisition systems.
  4. Audio equipment: High-fidelity audio recording and processing.
  5. Power management: Battery charging and energy monitoring.

Alternative Models

Here are some alternative models that offer similar functionality:

  1. ADS8320IDGK: 12-bit ADC with SPI interface.
  2. ADS1262IPW: 24-bit ADC with integrated PGA and temperature sensor.
  3. MCP3421E/SN: 18-bit ADC with I2C interface.

These alternative models provide options with different resolutions, interfaces, and additional features to suit specific application requirements.

In conclusion, the ADS8319IDRCR is a high-resolution analog-to-digital converter with fast sampling rate and low power consumption. It offers various integrated features and finds applications in diverse fields such as industrial automation, medical equipment, and audio processing.

技術ソリューションにおける ADS8319IDRCR の適用に関連する 10 件の一般的な質問と回答をリストします。

Sure! Here are 10 common questions and answers related to the application of ADS8319IDRCR in technical solutions:

  1. Q: What is the ADS8319IDRCR? A: The ADS8319IDRCR is a high-speed, 16-bit analog-to-digital converter (ADC) designed for precision data acquisition applications.

  2. Q: What is the maximum sampling rate of the ADS8319IDRCR? A: The ADS8319IDRCR has a maximum sampling rate of 500 kilosamples per second (ksps).

  3. Q: What is the resolution of the ADS8319IDRCR? A: The ADS8319IDRCR has a resolution of 16 bits, allowing for high-precision conversion of analog signals.

  4. Q: What is the input voltage range of the ADS8319IDRCR? A: The ADS8319IDRCR has a differential input voltage range of ±VREF, where VREF is the reference voltage supplied to the ADC.

  5. Q: Can the ADS8319IDRCR operate with a single-ended input signal? A: No, the ADS8319IDRCR requires a differential input signal for proper operation.

  6. Q: What is the power supply voltage range for the ADS8319IDRCR? A: The ADS8319IDRCR operates from a single power supply voltage ranging from 2.7V to 5.5V.

  7. Q: Does the ADS8319IDRCR have an integrated reference voltage source? A: No, the ADS8319IDRCR requires an external reference voltage source for accurate conversions.

  8. Q: What is the typical power consumption of the ADS8319IDRCR? A: The typical power consumption of the ADS8319IDRCR is 7.5mW at a 500ksps sampling rate.

  9. Q: Does the ADS8319IDRCR support serial communication interfaces? A: Yes, the ADS8319IDRCR supports both SPI (Serial Peripheral Interface) and QSPI (Quad Serial Peripheral Interface) communication interfaces.

  10. Q: What are some typical applications for the ADS8319IDRCR? A: The ADS8319IDRCR is commonly used in applications such as industrial automation, data acquisition systems, medical instrumentation, and test and measurement equipment.

Please note that these answers are general and may vary depending on specific implementation details and requirements.